Lynx Smart BMS 1000 (M10) - BMS for Lithium Smart batteries, 1000 A
Lynx Smart BMS 1000 (M10) is a dedicated Battery Management System for Victron Lithium Smart batteries and part of the modular Lynx distribution system. It integrates a 1,000 A contactor, used as a fallback safety mechanism and as a remote-controllable main switch, as well as a battery monitor and a pre-alarm signal.
Main features:
- Rated current: 1,000 A continuous, 1,200 A for 5 minutes
- System voltages: 12, 24 or 48 V
- Compatible batteries: Victron Lithium Smart
- Pre-charge: built-in circuit for capacitive loads such as inverters
- Charger/load control: DVCC, ATC/ATD contacts, programmable relay
- Connectivity: Bluetooth, VictronConnect, VE.Can, GX devices and VRM
The Lynx Smart BMS is a dedicated Battery Management System for Victron Lithium Smart Batteries. There are multiple BMS-es available for our Smart Lithium series of batteries, and the Lynx Smart is the most feature rich and complete option. It is available in two versions: 500A and 1000A (both with M10 busbar connections).
The main features are:
- Built-in 500A or 1000A contactor used as a fallback safety mechanism and also suitable as a remote controllable main system switch.
- Battery monitor, indicating state of charge percentage and more data.
- Pre-alarm signal: provide a warning before the system shuts down due to -for example- a low cell.
- Bluetooth for use with our VictronConnect app, for setup and monitoring, including Instant Readout - key data of the BMS at-a-glance.
- Local and remote monitoring using a Victron GX device, for example the Cerbo GX or Ekrano GX.
The Lynx Smart BMS is part of the modular Lynx Distribution system.
Technical specifications
| Voltage range | 9 … 60 V |
|---|
| Maximum input voltage | 75 V |
|---|
| Current rating | 1000 A |
|---|
| Peak current rating | 1200 A |
|---|
| System voltages | 12V or 24V or 48V |
|---|
| Reverse polarity protection | No |
|---|
| Power consumption (off) | 0.3mA for all system voltages |
|---|
| Power consumption (standby) | Approximately 0.6W (50mA at 12V) |
|---|
| Power consumption (on) | Approximately 4.2W (350mA at 12V) depending on the state of the relays |
|---|
| Pre-charge load resistance | 10Ω and above for 12V systems 20Ω and above for 24V and 48V systems |
|---|
| AUX output current rating | 1.1 A continuous, protected by resettable fuse |
|---|
| Allowed-to-charge output rating | 0.5A at 60VDC, protected by resettable fuse |
|---|
| Allowed-to-discharge output rating | 0.5A at 60VDC, protected by resettable fuse |
|---|
| Programmable relay | SPDT - 2 A at 60 VDC |
|---|
| Busbar material | Tinned copper |
|---|
| Busbar dimensions | 8mm x 30mm |
|---|
| Operating temperature range | -40 … 60 °C |
|---|
| Storage temperature range | -40 … 60 °C |
|---|
| Maximum humidity | 95 % |
|---|
| Busbar connections | M10 |
|---|
| VE.Can | RJ45 |
|---|
| I/O connection | Removable multi-connector with screw terminals |
|---|
| Battery communication terminals | Terminals with M8 circular connectors |
|---|
| Lynx Distributor fuse monitoring | RJ10 (RJ10 cables ship with each Lynx Distributor) |
|---|
| Material | ABS |
|---|
| Colour | Blue (RAL 5012) |
|---|
| Protection category | IP22 |
|---|
| Weight | 2.7 kg |
|---|
| Height | 230 mm |
|---|
| Width | 180 mm |
|---|
| Depth | 100 mm |
|---|
| Safety | EN-IEC 63000 |
|---|
| EMC (emission) | EN-IEC 61000-6-3 |
|---|
| Quality management system | NEN-EN-ISO 9001 |
|---|