Lynx Smart BMS 1000 NG (M10) is a battery management system (BMS) for Victron Lithium NG batteries of 12.8 V, 25.6 V and 51.2 V. It integrates a 1,000 A contactor, a battery monitor and a pre-alarm signal, and manages up to 50 batteries in series and parallel, in 12, 24 or 48 V systems.
Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
Lynx Smart BMS 1000 NG (M10) is a battery management system (BMS) for Victron Lithium NG batteries of 12.8 V, 25.6 V and 51.2 V. It integrates a 1,000 A contactor, a battery monitor and a pre-alarm signal, and manages up to 50 batteries in series and parallel, in 12, 24 or 48 V systems.
The Lynx Smart BMS NG is an advanced battery management system designed specifically for Victron Energy Lithium NG batteries (not to be confused with the Lynx Smart BMS, which is for Victron Lithium Battery Smart batteries). This robust BMS ensures uninterrupted performance, optimal safety and efficient monitoring for Lithium NG battery banks, which are available in nominal voltages of 12.8 V, 25.6 V and 51.2 V with different capacities. Available in two sizes - 500 A and 1000 A - the Lynx Smart BMS NG offers a reliable, safe and easy-to-use solution.
Battery systems can be configured in series, in parallel or in a combination of both, supporting 12 V, 24 V and 48 V systems. Each system can accommodate up to 50 batteries, providing up to 192 kWh (12 V) or 384 kWh (24 V/48 V) of energy storage. By paralleling several Lynx Smart BMS units, you can extend the capacity and ensure redundancy.
Key features:
The Lynx Smart BMS NG is an integral part of the modular Lynx Distribution system.
| Voltage range | 9 … 60 V |
|---|---|
| Maximum input voltage | 75 V |
| Rated current | 1000 A |
| Peak rated current | 1200 A |
| System voltages | 12 V or 24 V or 48 V |
| Power consumption (off) | 0.3 mA for all system voltages |
| Power consumption (standby) | Approx. 0.6 W (50 mA at 12 V) |
| Power consumption (on) | Approx. 4.2 W (350 mA at 12 V), depending on the relay state |
| Load resistance during pre-charge | 10 Ω and above for 12 V systems, 20 Ω and above for 24 V and 48 V systems |
| AUX output rated current | 1.1 A continuous, protected by a resettable fuse |
| Rating of the “allowed-to-charge” output | 0.5 A at 60 VDC, protected by a resettable fuse |
| Rating of the “allowed-to-discharge” output | 0.5 A at 60 VDC, protected by a resettable fuse |
| Programmable relay | SPDT - 2 A la 60 VDC |
| Busbar material | Tinned copper |
| Busbar dimensions | 8mm x 30mm |
| Operating temperature range | -40 … 60 °C |
| Storage temperature range | -40 … 60 °C |
| Maximum humidity | 95 % |
| Busbar connections | M10 |
| VE.Can | RJ45 |
| Battery communication terminals | Terminals with M8 circular connectors |
| Lynx Distributor fuse monitoring | RJ10 (RJ10 cables are supplied with every Lynx Distributor) |
| Material | ABS |
| Colour | Blue (RAL 5012) |
| Ingress protection | IP22 |
| Weight | 2.7 kg |
| Height | 230 mm |
| Width | 180 mm |
| Depth | 100 mm |
| Safety | EN-IEC 63000 |
| EMC (emission) | EN-IEC 61000-6-3 |
| Quality management system | NEN-EN-ISO 9001 |
We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the attached datasheet.
Compatibility is calculated automatically from the manufacturers’ technical data and is for information only. For complex systems, we recommend having the configuration checked by a consultant before ordering. Details in the Terms and conditions