- -20%
€103 Tax excluded
Smart BMS CL 12-100 is a battery management system for Victron Smart LiFePO4 batteries, designed for 12 V systems with a 12 V alternator. It monitors every cell and disconnects the alternator, the charge sources or the loads in the event of too low a voltage, too high a voltage or overtemperature, and the dedicated input limits the alternator current.
Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
Smart BMS CL 12-100 is a battery management system for Victron Smart LiFePO4 batteries, designed for 12 V systems with a 12 V alternator. It monitors every cell and disconnects the alternator, the charge sources or the loads in the event of too low a voltage, too high a voltage or overtemperature, and the dedicated input limits the alternator current.
Smart BMS CL 12/100 is a battery management system for smart lithium iron phosphate (LiFePO4) batteries. It has been designed specifically for 12 V systems with a 12 V alternator.
The BMS CL 12/100 monitors and protects every individual cell of the battery (or battery bank) and will disconnect the alternator, charge sources or DC loads in the event of low battery voltage, high battery voltage or excessive temperature.
The dedicated alternator input provides current limiting and one-way flow from the alternator to the battery, so an alternator of any size (and a starter battery) can be safely connected to the Smart Lithium battery or batteries.
The BMS is also equipped with a remote shutdown connector, to switch off the BMS (and the system) via a remote switch, and a pre-alarm contact, to give a warning signal before the BMS disconnects the batteries from the system.
| Nominal battery voltage | 12 V |
|---|---|
| Maximum current | 100 A |
| Maximum fuse rating | 125 A |
| Minimum input charging voltage | 13 V |
| Current consumption, remote on | 16 mA |
| Current consumption, remote off | 5 mA |
| Load disconnect output | Normally high level (Vbat - 0.1V) |
| Load disconnect output - current supplied | 10 mA |
| Charge disconnect output | Normally high level (Vbat - 0.1 V) |
| Charge disconnect output - current supplied | 10 mA |
| Pre-alarm output | Normally floating, high level (Vbat) on alarm, max. 1 A |
| Pre-alarm output rated current | 1 A |
| Remote terminals | Remote L and Remote H Operating modes for switching the system on/off: 1. ON when terminals L and H are connected together 2. ON when terminal L is pulled to the battery negative (V< 5 V) 3. ON when terminal H is at a high level (V>3 V) 4. OFF in all other conditions |
| Operating temperature range | -40 … 60 °C |
| Maximum humidity | 100 % |
| Power connection | M8 bolts |
| Battery negative connection | Faston terminal 6.3 x 0.8 mm |
| Battery communication terminals | Terminals with M8 circular connectors |
| Material | Aluminium |
| Colour | Blue (RAL 5012) |
| Protection rating | IP65 |
| Weight | 1.6 kg |
| Height | 65 mm |
| Width | 120 mm |
| Depth | 224 mm |
| Emissions | EN 55014-1, EN-IEC 61000-6-3 |
| Immunity | EN 55014-2, EN-IEC 61000-6-1, EN-IEC 61000-6-2 |
We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the attached datasheet.
Compatibility is calculated automatically from the manufacturers’ technical data and is for information only. For complex systems, we recommend having the configuration checked by a consultant before ordering. Details in the Terms and conditions