- -20%
€121 Tax excluded
The black Victron BMV-712 Smart battery monitor is a high-precision battery monitor with a rated current of 500 A that calculates consumption in amp-hours and the battery state of charge. The black version has built-in Bluetooth, an input for a second battery and a programmable relay. The battery capacity range is 1-9999 Ah, and communication is via VE.Direct.
Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
Battery Monitor Victron BMV-712 Smart black is a high-precision battery monitor with a 500 A shunt that calculates consumption in amp-hours and the battery state of charge. The black version has built-in Bluetooth, an input for a second battery and a programmable relay. It is flush-mounted and communicates via VE.Direct.
The essential function of a battery monitor is to calculate the amp-hour consumption and the state of charge of a battery. Amp-hour consumption is calculated by integrating the current flowing into or out of the battery. The built-in Bluetooth makes the monitor ready for the Internet of Things (IoT), and wireless communication between Victron Energy products simplifies system installation and improves performance. This version is black.
It has an auxiliary input for the voltage of a second battery (6.5-70 V), an optional temperature sensor (ASS000100000) and a 60 V / 1 A latching relay, normally open, whose function can be inverted.
| Supply voltage range | 6.5 … 70 VDC |
|---|---|
| Rated current | 500 A |
| Battery capacity range | 1 … 9999 Ah |
| Current consumption | 1 mA |
| Input voltage range, auxiliary battery | 6.5 … 70 VDC |
| Operating temperature range | -40 … 50 °C |
| Auxiliary input for second battery voltage | Yes |
| Temperature sensor | Optional (ASS000100000) |
| Temperature measurement range | -20 … 50 °C |
| Communication port | VE.Direct |
| Bluetooth | Yes |
| Programmable relay | Latching relay 60V / 1A, normally open (function can be inverted) |
| Display | Yes |
| Visual alarm on the device | Yes |
| Audible alarm on the device | Yes |
| Current measurement resolution | 0.01 A |
| Voltage measurement resolution | 0.01 V |
| Capacity measurement resolution | 0.1 Ah |
| State-of-charge measurement resolution | 0.1 % |
| Time-remaining measurement resolution | 1 min |
| Temperature resolution | 1 °C |
| Measurement accuracy | 0.4 % |
| Current measurement accuracy | 0.4 % |
| Voltage measurement accuracy | 0.3 % |
| Positive cable | 1.5 m cable with 1 A fuse |
| Auxiliary cable | 1.5 m cable with 1 A fuse |
| Shunt connection terminals | M10 screws |
| Display-to-shunt cable | 6-wire UTP, 10 meters, with RJ12 connectors |
| Colour | Black |
| Ingress protection | IP55 (not for outdoor use) |
| Installation | Flush mounting |
| Front diameter | 63 mm |
| Front frame | 69 x 69mm |
| Body diameter | 52 mm |
| Body depth | 31 mm |
| Shunt | 500A / 50mV |
| Safety | EN 60335-1 |
| Emission and immunity | EN 55014-1, EN 55014-2 |
| Automotive directive | ECE R10-4, EN 50498 |
| Stored data | Battery voltage, battery current, battery temperature, battery state of charge (%), battery midpoint deviation, starter battery voltage |
| Data retention period | 46 days |