Battery Management System Victron Energy VE.Bus BMS v2

€199 Save €40
€159 Tax included

€133 Tax excluded

The VE.Bus BMS V2 is a battery management system for one or more Victron Smart lithium batteries of 12.8 V and 25.6 V (LiFePO4), in systems with inverters or inverter/chargers with VE.Bus communication. The operating voltage at the DC input is 9-70 V and the consumption in normal operation is 10 mA.

Reference BMS300200200

Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions

Battery Management System VE.Bus BMS V2 - BMS for Victron Smart lithium batteries

VE.Bus BMS V2 is a battery management system (BMS) designed to interact with and protect one or more Victron Smart lithium batteries of 12.8 V and 25.6 V (LiFePO4), in systems with Victron inverters or inverter/chargers with VE.Bus communication.

Main features:

  • DC operating voltage: 9-70 V
  • Consumption in operation: 10 mA
  • Consumption when switched off: 1.5 mA
  • VE.Bus connection: 2 x RJ45
  • Protection rating: IP20
  • Operating temperature: -20 to 50 °C
  • Weight: 0.12 kg

The VE.Bus BMS V2 monitors and protects the batteries against overvoltage and undervoltage of any individual cell, as well as against temperatures that are too low or too high. The load disconnect, charge disconnect and pre-alarm outputs are normally high and become floating on alarm or on disconnect.

The terminals for communication with the battery have M8 circular connectors, the input/output terminals are screw terminals, and there are 2 RJ45 sockets for connection to VE.Bus products. The rated current is 1 A for the AUX input, the GX power supply output and the pre-alarm output. The recommended fuse size is between 0.3 A and 2.5 A, depending on the devices connected to the load disconnect output and to the pre-alarm output.

Technical specifications

DC input operating voltage range9 … 70 V
Current consumption (normal operation)10 mA
Current consumption (low cell voltage)2 mA
Current consumption (switched off)1.5 mA
AUX input rated current1 A
GX power supply output rated current1 A
Load disconnect outputNormally high (output voltage ≈ supply voltage - 1 V). Floating when the load must be disconnected
Load disconnect output - supplied current1 A
Charge disconnect outputNormally high (output voltage ≈ supply voltage - 1 V). Floating when the load must be disconnected
Charge disconnect output - supplied current1 mA
Pre-alarm outputNormally floating - On alarm: output voltage Vbat -0.1 V
Pre-alarm output rated current1 A
Operating temperature range-20 … 50 °C
Maximum humidity95 %
Battery communication terminalsTerminals with M8 circular connectors
Input/output terminalsScrew terminals
VE.Bus terminals2 x RJ45 sockets for connection to all VE.Bus products
Power cableRecommended fuse size 0.3 A - 2.5 (depending on the devices connected to the load disconnect output and to the pre-alarm output)
MaterialABS
ColourMatt black with blue sticker
Protection ratingIP20
Weight0.12 kg
Height23.8 mm
Width94.5 mm
Depth10.5 mm
SafetyEN 60950
EmissionEN 55014-1, EN-IEC 61000-6-3
ImmunityEN 55014-2, EN-IEC 61000-6-1, EN-IEC 61000-6-2
Automotive standardEN 50498

Data sheet

Reference
BMS300200200
Product type
BMS and BMS accessories
Communication interfaces
VE.Bus
Dimensions (H x W x D)
23.8 x 94.5 x 10.5 mm
Weight
0.12 kg
Ingress protection (IP)
IP20
Operating temperature
-20 ... 50 °C
Max. relative humidity
95 %
Colour
Black
Material
ABS plastic
Standards and compliance
EN 60950, EN 50498, EN 55014-1, EN-IEC 61000-6-3

We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the manufacturer’s datasheet.