MPPT solar charge controller Victron BlueSolar MPPT 100/20, 20 A, 12/24/48 V

€93 Save €19
€74 Tax included

€62 Tax excluded

BlueSolar MPPT 100/20 is an MPPT solar charge controller for 12/24/48 V batteries, with a charge current of 20 A, a maximum PV open-circuit voltage of 100 V and a maximum efficiency of 98 %. Communication is via VE.Direct, and the protection rating is IP22 (connection area), IP43 (electronics).

Reference SCC110020170R

Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions

BlueSolar MPPT 100/20 - MPPT solar charge controller for 12/24/48 V batteries

BlueSolar MPPT 100/20 is a solar charge controller with maximum power point tracking (MPPT), for 12/24/48 V batteries, with a charge current of 20 A and a maximum PV open-circuit voltage of 100 V. The VE.Direct port allows connection to a monitoring device, and Bluetooth is added via a dongle.

Main features:

  • Battery voltage: 12/24/48 V, automatic selection
  • Charge current: 20 A
  • Maximum PV voltage (Voc): 100 V
  • Maximum PV power: 290 W (12 V), 580 W (24 V), 1160 W (48 V)
  • Maximum efficiency: 98 %
  • Communication: VE.Direct
  • Protection rating: IP22 connection area, IP43 electronics

MPPT technology continuously monitors the voltage and current of the solar panels (PV) and tracks the maximum power point, and the advantage is most visible when the sky is partly cloudy and the light intensity keeps changing. The controller can also recharge a deeply discharged battery that is not permanently sulphated or otherwise damaged, and can operate from a battery voltage of 0 V.

The controller has no built-in Bluetooth; with a VE.Direct to Bluetooth Smart dongle, the information (for example battery status and solar panel power) can be viewed wirelessly on iOS and Android devices through the VictronConnect app. If the installation is connected to the internet through a GX device, the Victron Remote Management (VRM) portal gives access to the controller data; for locations without an internet connection, GlobalLink 520 can be used.

The load output prevents excessive discharge of the batteries: the voltage at which the loads are disconnected is configurable. The BatteryLife algorithm tries a full recharge every day and, if this fails in unfavourable weather, gradually raises the disconnect voltage to protect the battery and extend its service life.

Technical specifications

Battery voltage (automatic selection)12V / 24V / 48V (automatic selection)
Rated charge current20 A
Rated PV power (12 V)290 W
Rated PV power (24 V)580 W
Rated PV power (48 V)1160 W
Absorption charge voltage14.4V / 28.8V / 57.6V (adjustable)
Float charge voltage13.8V / 27.6V / 55.2V (adjustable)
Charge algorithmAdaptive multi-stage (adjustable)
Temperature compensation (12 V)-16 mV/°C
Temperature compensation (24 V)-32 mV/°C
Temperature compensation (48 V)-64 mV/°C
Maximum efficiency98 %
Self-consumption (load output on)12V: 26 mA / 24V: 20 mA / 48V: 19 mA
Self-consumption (load output off)12V: 10 mA / 24V: 8 mA / 48V: 7 mA
Maximum PV open-circuit voltage100 V
PV start-up voltagePV voltage must exceed Vbat + 5V for the controller to start. Afterwards, the minimum PV voltage is Vbat + 1V
Number of MPPT trackers1
Maximum PV short-circuit current20 A
Maximum continuous load current (12 V)20 A
Maximum continuous load current (24 V)20 A
Maximum continuous load current (48 V)1 A
Low-voltage load disconnect11.1V / 22.2V / 44.4V or 11.8V / 23.6V / 47.2V or BatteryLife algorithm
Low-voltage load reconnect13.1V / 26.2V / 52.4V or 14V / 28V / 56V or BatteryLife algorithm
ProtectionsAutomatic load disconnect, Output short circuit, Over-temperature, PV reverse polarity
Operating temperature range-30 … 60 °C
Maximum humidity95 %
BluetoothNo
Data communicationVE.Direct
Programmable relay–
Battery connection terminalsScrew terminals 6 mm² (10 AWG)
PV connection terminalsScrew terminals 6 mm² (10 AWG)
Load connection terminalsScrew terminals 6 mm² (10 AWG)
ColourBlue (RAL 5012)
Protection ratingIP22 (connection area), IP43 (electronics)
Weight0.65 kg
Height100 mm
Width113 mm
Depth60 mm
SafetyCSA C22.2, EN-IEC 62109-1, UL 1741

Data sheet

Reference
SCC110020170R
Brand
Victron Energy
Product type
MPPT controller
Maximum efficiency
98 %
Battery voltage
12 V
24 V
48 V
Charge current class
11-20 A
Max. charge current
20 A
Absorption charge voltage
14.4/28.8/57.6 V
Float charge voltage
13.8/27.6/55.2 V
Charge algorithm
Multi-stage adaptive (adjustable)
Max. PV voltage (Voc)
100 V
Max. PV short-circuit current
20 A
Max. PV power (by battery voltage)
290 W (12 V), 580 W (24 V), 1160 W (48 V)
Bluetooth (app)
No
Communication interfaces
VE.Direct
Protections
Output short-circuit, overtemperature, PV reverse polarity, automatic load disconnect
Dimensions (H x W x D)
100 x 113 x 60 mm
Weight
0.65 kg
Ingress protection (IP)
IP22 (connection area), IP43 (electronics)
Operating temperature
-30 ... 60 °C
Max. relative humidity
95 %
Colour
Blue
Standards and compliance
CSA C22.2, EN-IEC 62109-1, UL 1741