Cyrix-i 24/48V-400A is a high-current, microprocessor-controlled battery combiner for 24 V or 48 V systems. It automatically connects batteries in parallel when one of them is being charged and separates them when the voltage drops below float level, handling 400 A continuously with virtually no voltage loss, unlike diode isolators.
Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
Cyrix-i 24/48V-400A is a high-current, microprocessor-controlled battery combiner for 24 V or 48 V systems. It automatically connects batteries in parallel when one of them is being charged and separates them when the voltage drops below float level, handling 400 A continuously with virtually no voltage loss, unlike diode isolators.
The Cyrix Battery Combiner is a microprocessor controlled heavy duty relay that automatically connects batteries in parallel when one of them has reached a pre-set voltage (indicating that the battery is being charged), and disconnects when the voltage decreases below float level (indicating that one or more batteries are being discharged). Cyrix Battery Combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.
| Nominal battery voltage | 24V or 48V (automatic detection) |
|---|---|
| Input voltage range | 16 … 72 V |
| Continuous current | 400 A |
| Peak current rating | 2000 A |
| Connection profiles | See table on website |
| Overvoltage disconnect | 32V @24V / 64V @48V |
| Current consumption, open | 4 mA |
| Start assist | Yes, 30 seconds |
| Remote monitoring switch | Yes |
| LED status indication | Yes |
| Weight | 0.9 kg |
| Height | 78 mm |
| Width | 102 mm |
| Depth | 110 mm |
We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the attached datasheet.
12/24 V only. Fuse for 12 V and 24 V systems. Do not use it on 48 V.