- -20%
€678 Tax excluded
The MultiPlus-II 24/3000/70-32 230V is an inverter/charger for 24 V batteries, with a continuous power of 3000 VA (2400 W), a peak power of 5500 W, a maximum charging current of 70 A and a maximum efficiency of 94%. The transfer switch is rated at 32 A, parallel operation is possible and communication is via VE.Bus.
Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
MultiPlus-II 24/3000/70-32 230V is a multifunctional inverter/charger for 24 V batteries, with a continuous power of 3000 VA (2400 W), a peak power of 5500 W and a maximum charging current of 70 A. It combines the functions of MultiPlus and MultiGrid, with a 32 A transfer switch.
MultiPlus-II combines the functions of MultiPlus and MultiGrid. It has all the features of the MultiPlus, plus an option for an external current transformer for PowerControl and PowerAssist and for optimising self-consumption through external current sensing (maximum 32 A), and all the features of the MultiGrid, with built-in anti-islanding protection and a growing list of country approvals.
MultiPlus-II is the key component of a Victron ESS (Energy Storage System) and can be combined with MPPT solar chargers or grid-tied photovoltaic inverters.
PowerControl prevents overloading of the grid or generator, and PowerAssist increases the AC power during consumption peaks. In a power outage, the inverter switches over within milliseconds, keeping computers and sensitive electronic equipment running. The charger combines speed with efficiency through an intelligent adaptive algorithm that extends battery life, and the product supports parallel and three-phase configurations.
| Nominal battery voltage | 24 V |
|---|---|
| PowerControl | Yes |
| PowerAssist | Yes |
| Parallel operation | Yes |
| Three-phase operation | Yes |
| Number of AC inputs | 1 |
| Transfer switch rated current | 32 A |
| Maximum AC input current | 32 A |
| DC input voltage range | 19 … 33 VDC |
| AC output voltage | 230 VAC |
| AC output frequency | 50 Hz |
| Continuous output power at 25 °C (VA) | 3000 VA |
| Continuous output power at 25 °C (W) | 2400 W |
| Continuous output power at 40 °C | 2200 W |
| Continuous output power at 65 °C | 1700 W |
| Peak power | 5500 W |
| Maximum apparent feed-in power | 3000 VA |
| Maximum efficiency | 94% |
| No-load consumption | 13 W |
| No-load consumption in AES mode | 9 W |
| No-load consumption in search mode | 3 W |
| AC input voltage range | 187 … 265 VAC |
| AC input frequency range | 45 … 65 Hz |
| Absorption charging voltage | 28.8 VDC |
| Float charging voltage | 27.6 VDC |
| Storage mode charging voltage | 26.4 VDC |
| Charging algorithm | Adaptive, 4-stage |
| Maximum battery charging current | 70 A |
| Temperature sensor | Included |
| Number of AC outputs | 2 |
| Auxiliary output | Yes |
| External AC current sensor | 50A or 100A (optional) |
| Programmable relay | AC ratings: 230V / 4A, DC ratings: 4A up to 35VDC and 1A up to 60VDC |
| Protections | Output short circuit, overload, battery voltage too high, battery voltage too low, over-temperature, AC voltage at the inverter output, excessive DC ripple |
| Communication port | VE.Bus |
| General-purpose communication port | Yes |
| Remote control terminal | On / Off / Charger only |
| Programmable via computer | Yes |
| Operating temperature range | -40 … 65 °C |
| Fan-assisted cooling | Yes |
| Maximum humidity | 95% |
| Maximum altitude | 2000 m |
| AC connection terminals | Screw terminals 13 mm² (6 AWG) |
| Battery connection terminals | M8 screws |
| Remote terminal type | 2-pole screw terminal |
| Relay terminal | 3-pole screw terminal |
| VE.Bus terminal type | Two RJ45 connectors |
| Material | Steel |
| Colour | Blue (RAL 5012) |
| Protection rating | IP22 |
| Weight | 19 kg |
| Height | 499 mm |
| Width | 268 mm |
| Depth | 141 mm |
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 |
| Emission and immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, EN-IEC 61000-6-1, EN-IEC 61000-6-2, EN-IEC 61000-6-3 |
| Anti-islanding standard | Please refer to the certificates on our website |
| UPS standard | Please refer to the certificates on our website |